Buy Rotary Soot Blowers [Oman]

Name: Retractable and Rotary Soot Blowers,and Electrical Accessories

Usage: TSEP boilers

Spec:
retractable soot blowers

no. required:two sets per each system/boiler total4 set,

type:ful retractable.

long retractable of stroke:4500mm,

nozzle per blower,maxmum:2,

type of nozzle:venturi,subersonic

clearing radius:2.125,

nozzle to tube wall distance:300 mm,

operation:sequential,

location:shal be located in the area above superheater as shown in attached drawing.



Rotray soot blowers specs

type:rotray with patial retracting,

nozzle per blower: to be specified by the manufaturer.

element length: 2.611 mm,driven by electrical motors/Qty:3 per each system/boiler total 6 ,for short stroke rotary multijet soot blowers of stroke 300 mm

1.73 mm, driven by electrical motor/ Qty:12 per each system/poiler total 24, for short stroke rotary multijet sootblowers of strlke (300mm).

nozzle to tube wall distance:300mm

operation:sequential

location : shall be located in the area of economzer no 1,2, and 3,for dimensions, location of sootblowers and areas to be covered please refer to the attached drawing.




electrical accesories

motor specification

the electrical motors shal be weather proof IP55

winding insulation class to be class F material.

the motor must be induction type,squirrel cage, 3 phasees, 400 v,50 hz




electrical conyrol panel specification

no required: one set for each system

all electrical squential operation shall be controlled by PLC

power and control panels shall be IP55

separate breakers as well as contractors and overloads for each of the following to be provided:steam and drain valves.motors and controling

ammeters and voltmeter to be provided for main circuit breaker

the voltmeter to be connected as the input side of the breaker

electrical interlock between advanced and return contractors.




motor starter board specification:

all circuit shall be molded case 3 pole, 400 v, with suitable trip rating for service,the interrupting capacity of circuit breakers must be adequate for the available short circuit current not less than 40 ka r.m.s , circuit breakers shall have thermal/magmatic trip feature of adjustable range.

all motors starters shal be 3 poles,400 v ,AC3 eith thermal overload relay of suitable range, coil voltage to be 230 v ,50 hz,signal phase.




spare parts: spare parts list shall be provided with parts numbers cross referenced to relevant drawing



utilities available at site

service air: 6_7 kg/cm ,not dehydrated

instrument air :6-7 kg/cm ^2, dehydrated

barrage air(scavenging air): 2000 m^3/hr at 6000 pa pressure supplied by indepent fan

blowing steam:17.6 kg/cm^2 at 260 c, superheated


electrical steam: the electricall supply system is three phase,400 v for main motor the frequency 50 hz

Company Name:ELITE
Country:Oman
Add:P.O. Box 313, Hamriya, Postal Code 131, Sultanate of Oman
Tel:962-65517916
Fax:962-65510916
Website:http://www.elite-itc.net
Email:tamara@elite-itc.com
Contact Person: TAMARA ALHALABI

手机链接:http://m.vooec.com/global_47765.html
网站链接:http://www.vooec.com/global/47765.html

国际采购

国际贸易网 vooec.com 版权所有 网页版 B2B Marketplace
在线咨询:点击这里给我发消息  点击这里给我发消息