Buy Filter [India]
Type of Filter required Cartridge Filter
Fluid Handled Gas
Application Post Filter to Blower Reactivated Dryer
Flow rate (min.) kg/hr 118790
Flow rate (normal) kg/hr 130670
Flow rate (Max) kg/hr 180946
Inlet Pressure kg/cm2 (a) 28.1
Inlet Temperature Deg C 4 to 250
Particles to be removed
Size of the particles to be removed Micron 3 Microns & larger
Allowable pressure drop (clean) kg/cm2 0.1
Allowable pressure drop (Dirty) kg/cm2 0.2
Filtration Efficiency Remove 99% of all particles of 3 microns and larger
Fluid Properties @ op. pressure & temp
Density kg/m3 12.65
Viscosity cP 0.0145
Presence of Corrosive components No
Mechanical Data
Design Pressure kg/cm2 g 29.8
Design Temperature Deg C 250
Material of construction
Body KCS+PWHT
Filter Element SS 316 Mesh, Double open end with Welded end caps
Filter Element Model **
Filter Element Size 40"L x 76 mm Dia
Total Gross Filtering Area per Element sq. meter 0.24
No. of Filter elements /housing nos. 46
Filter Element Burst Pressure kg/cm2 5
Dirt Holding Capacity Please specify
Filter Element Collapsible Pressure kg/cm2 Please specify
Corrosion Allowance- Body mm 1.6
Corrosion Allowance- Element mm 0
Inlet/ outlet Size 16" NB, 300#
Total no. of cartridges required for this project 400 nos
Note:
1. Filter to be subjected to steam out conditions of 0.5 kg/cm2 and 200 Deg C